※ Download: Idrac license crack Pass serial port through iDRAC If we want women to be equally influential in politics, we have to crack all those other 26 Jul With the Express you are idrac license crack to being able to power the server on and off, and manage the Drac while monitoring the system.
Hardware Overview
- 2U Enterprise server
- Ships with one or two 750W or 1100W PSU
- Nodes are dual-socket Xeon E5-2600v3 or v4; supports 1 or 2 CPUs (max 145W).
- Can support two workstation-class CPUs (160W), but restrictions on drive and GPU type
- Many chassis versions including 8 x 3.5' disks, 12 x 3.5', 8 x 2.5', 24 x 2.5', also available with dual 2.5' and three 3.5' rear drive options
- Ships with 3 x std-profile, 3 x low-profile and 2 x full-width PCI slots as standard
- GPU kit available (factory fit only) which can support 2 x passive 335W GPUs, leaving 3 x low-profile slots available
- 24 DIMM slots; requires 1 DIMM to boot; max of 1.5TB RAM (24 x 64GB); slots 8-16 require CPU2 to be installed; DIMM slot enumeration printed on chassis lid underside and matches PCB printing
- Ships with iDRAC8 express (shared IPMI LAN port, no KVM-over-IP) or iDRAC enterprise with dedicated port
Profile 'Cluster Slave'
BIOS configuration
- Power on and press F2 to enter 'System Setup'
- Enter System BIOS and configure the following:
N.B. exit this screen by pressing ENTER, not ESC (which cancels changes)
- Note configuration details on asset record sheet
iDRAC configuration
- Configure iDRAC in BIOS as per iDRAC options in the BIOS configuration (above)
- Configure user/password network information via ipmitool using the following parameters
- N.B. password for user must be at least 8 characters, contain capital letters and numbers
- iDRAC serial console is connected to ttyS1 (COM2) speed 115,200 parity 8n1.
Upgrading firmware
- Two primary firmware payloads are required which must be compatible with each other. Firmware must be applied in the following order:
- iDRAC firmware; can be upgraded from Linux without restarting node
- BIOS; new firmware is uploaded to iDRAC and applied by lifecycle manager on the next reboot. Failsafe firmware ROM automatically stores backup copy of firmware.
- Other component firmware may also be required:
- Hard disks; usually ship with recent firmware when new, but update may be needed if drives are replaced
- NIC; usually ship with latest firmware, but may need to be updated for new features/better performance
- PERC (RAID card); usually ships on latest version, but may need update for older systems
- Infiniband; Mellanox HBAs regularly ship with old firmware and should always be updated from Linux
- Firmware can be applied from Linux using a BIN file, or from a bootable DOS environment.
- Linux firmware upgrade is safe for BIOS (ROM is loaded to BMC first then applied on the next reboot), but can damage the machine if an iDRAC firmware is interrupted. Take precautions to ensure that power will not be interrupted during firmware update procedure.
- All DOS firmware upgrades may damage the machine if interrupted while running.
Download new firmware from Dell support site.
If using the Linux update binaries, execute the iDRAC and BIOS update packages on the nodes. The command line switches
-f -n -q
will cause the update packages to run automatically without prompting or rebooting. iDRAC updates can take up to 30 minutes to apply, and BIOS takes around 20 seconds to install (and a reboot to apply).If using DOS firmware update packages, boot into DOS and run the updates one by one. You don't need to reboot after each one, but reboot at the end of the process. The DOS environment can be delivered via USB boot, or via PXE boot.
BIOS settings usually persist across firmware updates
Configuring BIOS and iDRAC settings
Dell provides tools to perform BIOS and BMC configuration settings from Linux. The tools often produce inconsistent behaviour when setting the configuration (depending on the installed firmware version), but are generally fairly reliable for reading the current settings in place from BIOS.
- Tools are available from the Dell support site in the 'DTK' package
- Most successful version historically has been 'dtk_4.3_350_A00_Linux64.iso'
- Install the following packages ONLY:
- syscfg-4.3.0-4.33.4.el6.x86_64.rpm
- srvadmin-deng-7.3.0-4.13.2.el6.x86_64.rpm
- srvadmin-hapi-7.3.0-4.12.3.el6.x86_64.rpm
- srvadmin-isvc-7.3.0-4.21.4.el6.x86_64.rpm
- srvadmin-omilcore-7.3.0-4.72.1.el6.x86_64.rpm
- Once installed, start the firmware management service with:
- Use the syscfg utility to view and change BIOS and iDRAC settings
RAID disks and storage
The R730 can be supplied with:
- No RAID controller; supports SATA disks or SSDs, or no disks at all. This configuration required no hardware setup. SAS disks are not supported without a RAID controller. RAID controller slot is empty but cannot be used for anything else.
- Supports PCI-express SSDs mounted in the front disk bays. These do not require a RAID card.
- PERC H330 SAS controller in onboard RAID controller slot; Supports RAID0+1 only - see hardware asset record for RAID setup info.
- PERC H730 SAS controller in onboard RAID controller slot; includes battery (in dedicated internal slot) and 1GB RAM - PERC H730P controller has 2GB RAM; Supports RAID 0,1,5,6 - see hardware asset record for RAID setup info.
- Requires Nagios SMART disk monitor is no RAID card is installed.
- Requires Nagios RAID monitor if SAS RAID card is installed.
Compatible devices
R730 always ships with one of the following NIC daughercards:
- 4 x 1Gb RJ45 ports, Intel or broadcom
- 2 x 10Gb SFP+ ports and 2 x 1Gb RJ45 ports, Intel or Broadcom
- 2 x 10Gb RJ45 and 2 x 1Gb RJ45 ports, Intel or Broadcom
All ports can be configured for PXE and iSCSI boot, and iDRAC can share any port, on the base or a tagged VLAN.
The following list of hardware is certified for installation:
- Mellanox QDR and FDB, single and dual-port PCI-express and mez HCA; FDR cards can be factory installed
- Intel/Qlogic Omnipath QDR Infiniband PCI-express and mez HCA
- Intel and Broadcom, dual-port 10Gb SFP+ and 10G-baseT (copper) PCI-express and mez cards
- Quad-port Intel gigabit NIC
- 12Gb and 6Gb SAS HBA, FC cards, PERC H830 external RAID card
- Nvidia passive GPUs (Tesla series) and Xeon Phi add-in cards up to 335W; does not support active GPU cards
Hardware support
- Call Dell on 01344-860456 with the service tag for the machine.
- asset tag is printed on a pull-out tag on the front of the chassis with a QR code
- Use this to convert tags to express service codes
Fault finding may require a DSET report to be generated. Use the latest available DSET revision, and use 'RHEL6' or 'RHEL7' as the OS type. DSET will not install or run properly if the LSI MegaCLI monitor is installed, so use RPM to remove this first and YUM to install it again afterwards if necessary.
Known issues
- Firmware upgrade tools may fail to run without various Linux dependencies
- Software BIOS setting tools produce inconsistent results
- Older iDRAC firmware had memory leaks which caused the entire server to fail after several months of running; this is fixed in recent versions, but the bug has been reintroduced more than once in the past
- Disks, PSUs and fans are technically hot-swappable (although difficult to reach fans when powered)
- iDRAC processors can ship with SD cards (called Vflash) which presents as /dev/sda in Linux, causing problems installing an OS; remove these cards if installed from the rear of the chassis, or internally from both sides of the PCI slot riser closest to the PSUs
- IPMI sensors will fail to detect redundant PSUs properly if iDRAC is not set to 'redundant' power; if this happens, login to the iDRAC using a web browser and check the power settings. Older firmware had a bug whereby PSU redundancy would change by itself after many months of running. Mode sometimes needs to be manually set to non-redundant and saved, then set back to redundant mode again before ipmi-sensors will report properly.
- Does not support consumer grade GPUs with fans
- Mellanox Infiniband cards usually ship with Ethernet-only firmware installed if they are factory-fitted
- 12-drive 3.5' and 24-drive 2.5' chassis have no iDRAC LCD display
I have an iDRAC7 that came with an Express License. I have purchased an Enterprise license. What do I need to do to activate the license on my iDRAC7?
2 Answers
You'll have to go through the DRAC's web interface to apply it. (I've tried using radacm
from a Linux install on the system--racadm license import -f <filename>
should work--but I keep getting told that my iDRAC doesn't support racadm
commands.)
From the BIOS, press F2 to enter System Setup and go to 'iDRAC Settings'. Configure its network and its user account. Exit the system setup, saving your changes as prompted, and let the system reboot. Once the DRAC is accessible on the network, visit it with a web browser, log in, and go to the Overview > Server > Licenses page. On the 'iDRAC' line, under the 'License Options' drop-down menu, click 'Import'. Select the license XML file you obtained earlier and click 'Apply'.
At this point you should reboot your system once more, as the documentation indicates that some features may not be available until the system has been fully power cycled.
MadHatterFirst I test the racadm account locally:
racadm getsysinfo
And if that works drop the XML file on that systems desktop and do the following:
racadm license import -f 'C:somepathlic.xml' -c idrac.embedded.1
You should see the license type output afterwards.